Baxi boiler error codes explained

Baxi boilers are renowned for their reliability and efficiency, but like all complex appliances, they can occasionally encounter issues.

When something goes wrong, your Baxi boiler will display an error code to help you diagnose the problem quickly. Understanding these error codes can save you time and money by allowing you to troubleshoot minor issues yourself or communicate effectively with a Gas Safe registered engineer.

In this guide, we'll explore the most common Baxi boiler error codes across various models. We'll provide clear explanations and possible causes to help you get your heating system back up and running.

Baxi boiler fault and error codes by model

Here’s a detailed guide to Baxi boiler error codes, categorised by model. These codes provide insight into specific issues, allowing for timely maintenance or repairs.

Baxi Platinum error codes

Baxi Platinum boilers are known for their efficiency and durability. Below is a list of common error codes for this model.

Fault CodePossible Cause
E20Central heating NTC (Negative Temperature Coefficient) thermistor error.
E28Flue NTC thermistor error. Possible air pressure switch fault, blocked flue or condensate pipe, or wind fault affecting the flue.
E50Hot water NTC thermistor error.
E110Safety thermostat activated due to overheating.
E119Water pressure switch not operated—indicates low water pressure.
E125Primary circuit circulation fault—could be due to pump failure or airlock.
E130Flue NTC thermistor activated—flue gas overheating.
E133Gas supply issue or flame failure detected.
E160Fan fault or fan wiring error.
E193Pre-circulation fault—issue with the pump or circulation.

Baxi EcoBlue Error Codes

The Baxi EcoBlue range offers compact and efficient boilers, but like all systems, they can experience faults. Here’s a breakdown of common error codes.

Fault CodePossible Cause
110Boiler overheated—try bleeding your radiators to release trapped air.
117Water pressure too high—should be between 1.0 and 2.0 bar.
118Water pressure too low—below 0.5 bar; needs repressurising.
125Water circulation fault—possible pump issue or airlock in the system.
133Safety time to establish flame exceeded—possible gas supply issue or ignition fault.
E10Outdoor sensor error—sensor faulty or not connected properly.
E20Central heating thermistor sensor fault—could be short-circuited or disconnected.
E28Flue thermistor fault—sensor issue or flue blockage.
E54Domestic hot water (DHW) flow sensor fault—sensor faulty or wiring issue.
E78Water pressure sensor fault—sensor malfunctioning or not connected properly.
E100Internal clock time error on printed circuit board (PCB)—PCB may need resetting or replacing.
E109Poor circulation—possible pump failure or blockage in the system.
111Maximum limit of flow temperature exceeded—boiler is too hot; may indicate a sensor fault or circulation issue.
119System pressure too low—needs to be increased to the recommended level.
127Legionella protection temperature not reached—water not heated to sufficient temperature to kill bacteria.
128Loss of flame during operation—possible gas supply issue or ignition fault.
153Forced reset unit unlocked—manual reset required.
160Fan fault—fan not operating correctly or wiring issue.
162Air pressure switch error—faulty switch or blocked flue.
164Pressure sensor error (UK) or heating flow switch error (Ireland)—sensor may be faulty or disconnected.
166Air pressure switch fault—switch not responding as expected.
270Dry fire—boiler has detected low water levels; may need repressurizing.
432Earth connector error—possible electrical issue; check connections.
433Heat exchanger temperature exceeded (greater than 95°C)—possible circulation issue or sensor fault.

Baxi EcoBlue Advance / Ecoblue Regular Gas Boiler Flashing Light error codes

The Baxi EcoBlue Advance and Regular models use flashing lights to indicate faults. The number and color of flashes can help diagnose the issue.

Fault CodePossible Cause
1 green flashBoiler temperature reached set point. No action required.
3 green flashesTemporary flame loss. Boiler will self-reset. If the fault continues, it will display 3 red flashes.
4 green flashesCommunication error between PCB and control. Temporary error; boiler should self-reset.
5 green flashesParameter error on PCB. Temporary error; boiler should self-reset.
6 green flashesMiscellaneous error. Temporary error; boiler should self-reset.
1 red flashSensor error—temperature fault or flow fault. Boiler may need resetting or sensor may need replacing.
2 red flashesBoiler overheat tripped. Allow boiler to cool and reset. If it persists, bleed radiators or check circulation.
3 red flashesIgnition fault—boiler has attempted to light 5 times and failed. Check gas supply or call an engineer.
4 red flashesFan fault—fan not operating correctly; may need professional inspection.
5 red flashesParameter storage unit (PSU) error—issue with settings storage; may need engineer to reprogram or replace PSU.
6 red flashesMiscellaneous error—boiler requires resetting or professional diagnosis.

Baxi Duo-tec/Megaflo error codes

Below are common error codes for the Baxi Duo-tec and Megaflo boiler models.

Fault CodePossible Cause
E10Outdoor sensor fault—sensor may be faulty or disconnected.
E20Central heating thermistor sensor error—sensor issue causing incorrect temperature readings.
E28Flue thermistor error—possible blockage in flue or sensor fault.
E110Boiler overheat error—boiler temperature too high; may need bleeding or circulation checked.
E119Low water pressure error—pressure below required level; needs repressurizing.
E125Primary water circulation error—possible pump failure or airlock.
E131Flue overheat lockout error—flue gases too hot; may indicate blockage or sensor fault.
E133Ignition error—boiler failed to ignite; could be gas supply issue or ignition fault.
E160 / E161Fan error—fan not running correctly or wiring issue.
E164Pressure sensor fault—sensor not reading correctly; may need replacing.
E167PCB error—issue with the printed circuit board; may require professional attention.
E168PCB lockout error—boiler has locked out due to a PCB fault.
E193Circulation error—issue with water flow in the system; check pump and radiators.

Baxi 200 / 400 Combi Gas Boiler error codes

The Baxi 200 and 400 Combi boilers are compact and efficient. They use a combination of letters and numbers to indicate faults.

Fault CodePossible Cause
H.01 – .00Loss of communication between gas valve and boiler board—possible fault in air/gas unit or loose connection to gas valve.
H.01 – .05Difference between flow and return temperature too high—sensor error or insufficient circulation.
H.01 – .08Sensor fault—flow temperature increasing too fast in heating mode; could indicate insufficient circulation.
H.01 – .14Maximum flow temperature value exceeded—temporary fault due to insufficient circulation.
H.01 – .18No water circulation—insufficient circulation or sensor error.
H.01 – .21Temporary error—flow temperature increasing too fast in DHW mode; check for circulation issues or sensor faults.
H.02 – .02Temporary error—no input of parameters C1/C2; PCB not configured properly.
H.02 – .03Temporary error—incorrect configuration settings C1/C2.
H.02 – .04Temporary error—parameter fault; incorrect settings.
H.02 – .06Temporary error caused by system water pressure—possible water leak in boiler or system.
H.03 – .00Temporary communication error with NTC or flue sensor—sensor may be unconnected or have a bad connection.
H.03 – .01Communication error with the PCB.
H.03 – .02Flame error—no flame detected during operation.
E.00 – .04Return temperature sensor open-circuit—sensor not connected or faulty.
E.00 – .05Return temperature sensor short-circuit—sensor may be damaged or improperly connected.
E.01 – .02Temperature measured by return sensor greater than flow sensor—possible sensor fault or reversed connections.
E.01 – .04Loss of flame detected 5 times in 24 hours—possible gas supply issue or ignition fault.
E.01 – .11Incorrect fan speed—external draught over the boiler or defective gas/air unit.
E.01 – .12Requires reset—temperature measured by return sensor greater than flow temperature; check sensors and circulation.
E.01 – .17Reset the boiler—no circulation; sensor fault either not connected or has a bad connection.
E.01 – .20Maximum flue gas temperature reached—no circulation or sensor fault.
E.02 – .00Reset button has been pressed—boiler is resetting.
E.02 – .07No or low system water pressure—system pressure less than 0.5 bar; needs repressurizing.
E.02 – .16Permanent fault caused by channel service unit (CSU) time-out or PCB damage.
E.02 – .17Loss of communication between gas valve and boiler PCB or fault in air/gas unit.
E.02 – .19Jumper 1 changed—check position of jumper 1 on the PCB.
E.02 – .20Jumper 2 changed—check position of jumper 2 on the PCB.
E.02 – .21Jumper 3 changed—check position of jumper 3 on the PCB.
E.02 – .47Wiring to external device error—check connections to external controls or devices.
E.02 – .48Configuration to external device unsuccessful—check pairing or settings with external device.
E.04 – .00Gas valve error—gas valve not detected; could be a wiring issue or faulty valve.
E.04 – .01Flow temperature sensor short-circuited—sensor not connected properly or faulty.
E.04 – .02Flow temperature sensor open-circuited—sensor not connected properly or faulty.
E.04 – .03Critical flow temperature reached—non-existent or insufficient circulation.
E.04 – .04Flue temperature sensor short-circuited—sensor not connected properly or faulty.
E.04 – .05Flue temperature sensor open-circuited—sensor not connected properly or faulty.
E.04 – .06Critical flue gas temperature value reached—no circulation or sensor fault.
E.04 – .08Maximum safe temperature value reached—safety thermostat open-circuited; no circulation or sensor fault.
E.04 – .10Failure to light—could be a gas supply issue or ignition fault.
E.04 – .12False flame signal—ionisation current detected without flame; possible short-term fluctuation or defective gas/air unit.
E.04 – .13Fan rotor blocked—fan seized or wiring to fan damaged.
E.04 – .17Problem with gas valve or defective gas/air unit—may need professional inspection or replacement.

Baxi 600 Combi Gas Boiler fault codes

The Baxi 600 Combi is a compact and high-efficiency boiler. If you encounter an error code, refer to the table below.

Fault CodePossible Cause
E09Gas valve connection cable fault—check wiring to gas valve.
E10External probe fault—sensor may be faulty or disconnected.
E12Differential water flow switch fault (still open)—switch may be stuck or faulty.
E13Differential water flow switch fault (still closed)—switch may be stuck or faulty.
E15Gas valve command fault—issue with gas valve operation; may need replacing.
E20Central heating NTC thermostat fault—sensor issue causing incorrect temperature readings.
E28Flue NTC thermostat fault—sensor issue or flue blockage.
E40Central heating return NTC thermostat fault—sensor may be faulty or disconnected.
E50DHW NTC thermostat sensor fault—sensor short-circuited (s.c.) or open-circuited (o.c.); may need replacing.
E83/E84/E85/E86/E87No communication—issues with PCB or wiring; may need professional diagnosis.
E109Pre-circulation fault—issue with pump or blockage in the system.
E110Boiler max temperature exceeded—probable pump jammed or air in the circuit; safety thermostat may have tripped.
E118Primary system water pressure too low (< 0.5 bar)—needs repressurizing.
E125Circulation fault (primary)—possible pump failure or airlock.
E128Frequent flame failure (12 times)—possible gas supply issue or ignition fault.
E129Safety error due to frequent loss of flame with max correction during ignition—may need professional attention.
E130Flue thermostat sensor tripped (lockout)—flue gases too hot; may indicate blockage or sensor fault.
E133Failure to light—possible gas supply issue or ignition fault.
E134Elapsed time gas valve open without gas—short request in a short period; may indicate gas supply issue.
E135Interruption of gas supply (internal error)—possible gas valve or PCB issue.
E154Flow/return sensor temperature test—sensors may need checking or replacing.
E160Fan or fan wiring fault—fan not operating correctly; may need professional inspection.
E163DHW NTC thermostat sensor fault (s.c. or o.c.)—sensor may be faulty or disconnected.
E270Circulation fault (dry fire)—boiler has detected low water levels; may need repressurizing or pump inspection.
E317Wrong power supply electrical frequency (Hz)—check electrical supply; may need professional electrician.
E321Hot water NTC fault—sensor issue affecting hot water temperature readings.
E384False flame detected—ionisation current detected without flame; possible PCB or gas valve issue.
E385Under voltage—electrical supply voltage too low; contact electricity provider.
E430Water pressure temporary test—boiler is testing water pressure; no action required unless accompanied by other errors.
E430 + Flame ‘crossed’Water pressure test failed—system pressure issue; may need repressurising or leak inspection.

Baxi MainEco error codes

The Baxi MainEco is designed for ease of use and efficiency. Flashing lights indicate error codes on this model.

Fault CodePossible Cause
1 Green FlashBoiler temperature reached set point—no action required.
3 Green FlashesTemporary flame loss—boiler should self-reset. If fault persists, professional attention may be needed.
4 Green FlashesCommunication error between PCB and control—temporary error; boiler should self-reset.
5 Green FlashesParameter error on PSU or PCB—temporary error; boiler should self-reset.
6 Green FlashesMiscellaneous error—temporary error; boiler should self-reset.
1 Red FlashSensor error—temperature fault or flow fault; boiler may need resetting or sensor may need replacing.
2 Red FlashesBoiler overheat tripped—allow boiler to cool and reset. If it persists, bleed radiators or check circulation.
3 Red FlashesIgnition fault—boiler has attempted to light 5 times and failed; check gas supply or call an engineer.
4 Red FlashesFan fault—fan not operating correctly; may need professional inspection.
5 Red FlashesPSU error—issue with settings storage; may need engineer to reprogram or replace PSU.
6 Red FlashesMiscellaneous error—boiler requires resetting or professional diagnosis.

Baxi Avanta Range fault codes

The Baxi Avanta range includes compact boilers suitable for various home sizes. If you encounter an error, refer to the table below.

Fault CodePossible Cause
E0Temperature sensor fault—sensor may be faulty or disconnected.
E1Overheated—try bleeding your radiators to release trapped air.
E2Poor circulation—possible pump issue or blockage; try bleeding your radiators.
E3PCB fault—issue with the printed circuit board; may require professional attention.
E4Ignition failure—boiler failed to ignite; could be gas supply issue or ignition fault.
E10Poor or no circulation—check pump operation and bleed radiators.
E12PCB fault—issue with the printed circuit board; may require professional attention.
E13Heat exchanger thermal fuse tripped—boiler has overheated; may indicate circulation issues.
E83 / E84 / E85 / E86 / E87Fan fault—typically displayed as E8; fan may not be operating correctly or wiring issue.

Baxi GA Range error codes

The Baxi GA range includes high-efficiency boilers with advanced controls. Below are common error codes for this range.

Fault CodePossible Cause
E53Poor combustion—flue terminal may be blocked; check for obstructions.
E110Overheated—try bleeding your radiators to release trapped air.
E117System water pressure high—should be between 1.0 and 2.0 bar; try bleeding water from your radiators.
E118System water pressure low—below 0.5 bar; needs repressurizing.
E125Overheat—possible circulation issue; try bleeding your radiators.
E133Gas supply fault—boiler not receiving gas; check gas supply or contact provider.
E4Ignition failure—boiler failed to ignite; could be gas supply issue or ignition fault.
E09Gas valve wiring fault—check wiring to gas valve.
E10Outdoor sensor error—sensor may be faulty or disconnected.
E15Gas valve connection fault—issue with gas valve operation; may need replacing.
E20Central heating thermistor sensor fault—sensor issue causing incorrect temperature readings.
E28Flue thermistor fault—sensor issue or flue blockage.
E40Central heating return thermistor fault—sensor may be faulty or disconnected.
E55Calibration required—boiler needs to be calibrated; may require professional service.
E78Water pressure sensor fault—sensor malfunctioning or not connected properly.
E92Combustion test alarm during auto-setting—may require professional attention.
E109Poor circulation—possible pump failure or blockage in the system.
E128Loss of flame during operation—possible gas supply issue or ignition fault.
E129Loss of flame during calibration—may need professional attention.
E135Internal error—possible PCB or gas valve issue.
E154Primary flow fault—issue with water flow; check pump and circulation.
E160Fan fault—fan not operating correctly; may need professional inspection.
E270Dry fire—boiler has detected low water levels; may need repressurizing or pump inspection.
E317Wrong power supply (Hz)—check electrical supply; may need professional electrician.
E321Hot water thermistor fault—sensor issue affecting hot water temperature readings.
E384Flame detected when gas valve off—possible gas valve fault or PCB issue.
E385Low voltage (less than 195V)—electrical supply voltage too low; contact electricity provider.

Baxi Solo fault codes

The Baxi Solo is a range of conventional boilers. Error codes are indicated through a combination of flashing lights.

Fault CodePossible Cause
FLASH FLASH ONFan error—fan not operating correctly; may need professional inspection.
FLASH OFF FLASHVoltage less than 180V—electrical supply voltage too low; contact electricity provider.
FLASH OFF ONOverheat lockout—boiler has overheated; allow to cool and reset.
FLASH ON FLASHPCB error—issue with the printed circuit board; may require professional attention.
FLASH ON ONPCB fault—printed circuit board may need replacing.
OFF OFF OFFNo power—check electrical supply and fuses.
ON FLASH FLASHCirculation error or dry fire—check pump operation and system pressure.
ON FLASH ONThermistor error—temperature sensor fault; may need replacing.
ON OFF FLASHLive and neutral reversed error—electrical wiring issue; consult a professional electrician.
ON OFF ONIgnition lockout error—boiler failed to ignite; could be gas supply issue or ignition fault.
ON ON FLASHPCB error—issue with the printed circuit board; may require professional attention.
ON ON ONLow voltage wiring harness error—issue with wiring; may need professional inspection.

Error code E133 and E28

If you're seeing E133 or E28 error codes on your Baxi boiler, it's likely due to a frozen condensate pipe. In cold weather, the condensate pipe, which runs outside, can freeze and block, causing these errors.

How to fix

  • Thaw the condensate pipe: Gently pour warm (not boiling) water over the pipe to melt the ice blockage. Alternatively, use a hot water bottle or heat wrap as a compress.
  • Reset the boiler: Once the pipe is clear, reset your boiler to see if it resumes normal operation.

When to call a professional

Some boiler problems can be solved with a few simple checks, but anything involving the gas supply, the inside of the boiler, or a fault that keeps coming back needs a Gas Safe registered engineer. Never remove the boiler casing or attempt internal repairs yourself.

JustFix engineers can diagnose the fault, explain what's needed and what it'll cost before any work starts, and get your heating and hot water back up and running. All our work is backed by our 12-month workmanship guarantee.

Need a hand? Tell us what's going on and we'll take it from there.